• logo_aveva_header_plant

AVEVA Nuclear Room Manager

Specialist software for designing nuclear structures by Volume or Area

AVEVA Nuclear Room Manager is a specialist add-on for AVEVA PDMS. It enables the PDMS design of a nuclear plant on a per-Room basis.
AVEVA Nuclear Room Manager is in current production use on new-build nuclear plants.

 
Nuclear Room Manager is in use today (Image courtesy TVO)Nuclear Room Manager is in use today (Image courtesy TVO)
  • ~/media/Aveva/English/Products/Images/Nuclear Concrete/AVEVA_Nuclear_Concrete_Design_01.ashx?w=307&h=206&bc=whiteNuclear Room Manager is in use today (Image courtesy TVO)Nuclear Room Manager is in use today (Image courtesy TVO)
  • ~/media/Aveva/English/Products/Images/Nuclear Room/AVEVA_Nuclear_Room_Manager_01.ashx?w=307&h=206&bc=whiteNuclear plants have complex structures (Image: CEZ)Nuclear plants have complex structures (Image: CEZ)
  • ~/media/Aveva/English/Products/Images/Nuclear Room/AVEVA_Nuclear_Room_Manager_03.ashx?w=307&h=206&bc=whitePiping is designed as a system... (Image: CEZ)Piping is designed as a system...         (Image: CEZ)
  • ~/media/Aveva/English/Products/Images/Nuclear Room/AVEVA_Nuclear_Room_Manager_02.ashx?w=307&h=206&bc=white...but the building is also designed by room (Image: CEZ)...but the building is also designed by room (Image: CEZ)

Increased functionality

  • Allows volumes (Rooms) to be defined within the PDMS 3D model, with Room-specific parameters such as temperature, pressure, radiation level etc.
  • Rooms may be combined by Construction Area, Fire Safety Zone, building level etc.
  • Accurate material take-off (MTO) and inventories can be automatically produced by individual Room, or by any combination of Rooms that comprise a Construction area or Fire Safety Zone. Room definitions stored in PDMS can then be used to derive environmental conditions for analyses such as flooding, painting, or maintenance studies.

Nuclear Room Manager works seamlessly with AVEVA PDMS and AVEVA Nuclear Concrete Design.

Nuclear Room Manager provides data for multiple purposes, such as:

Preparing deliverables

  • Planning design, prefabrication and construction schedules
  • Spillage and flooding analysis
  • Painting and ventilation air requirements
  • Hazard studies

Inventory control

  • Calculates and maintains a complete inventory of each Room.

Environment-related information

  • Display Room numbers on documents
  • Derive local environment conditions for design and safety calculations

Materials efficiency

  • Automatically create accurate Inventory Lists for construction planning and materials allocation.

Save time and cost

  • Generate detailed drawings for regulatory and construction purposes.
  • Improve productivity in quality and integrity checking.

Eliminate errors

  • Data integration with the plant design provides a single, accurate and consistent basis for key studies.

Easy to adopt

  • Adds intuitive functionality to the familiar PDMS environment.

For more information, download our product literature:

AVEVA Nuclear Room Manager brochure